VPR-H-FCT
Availability: | |
---|---|
Quantity: | |
Product Description
Product description:
· Exceptional linearity ranging from 1A to 500kA
· Extensive range of operation
· Highly beneficial for conducting measurements on bulky or irregularly shaped conductors or in areas with restricted accessibility
· No risk of harm from an open-circuited secondary
· Immune to damage caused by substantial overloads
· Non-invasive, requiring no power drawn from the primary source
· Consistent measurement accuracy regardless of the position of the conductor within the coil
· Outstanding ability to reject external current conductors
H-FCT is a flexible current transducer based on Rogowski principle, particularly suitable for measurement in combination with portable devices. H-FCT coils are available in different sizes and can be supplied according to customer’s design, therefore they can be used in all those applications, in which traditional transducers are not fitting due to its size and/or weight.
Due to its specific features, flexible Rogowski coil is an extremely confortable solution for current measurement and can be used in a number of cases where traditional current transducer is not the adequate solution.
The H-FCT coil is designed to protect against outside magnetic fields, ensuring consistent measurements for a wide range of currents. To compensate for the 90° phase shift and equalize frequencies, the Rogowski coils need to be connected to an electronic integrator. However, our DIN-RAIL and panel meters can directly interface with Rogowski coils, eliminating the need for external integrators. This is advantageous because it eliminates the need for external boxes or power supplies, making it easier to use. The unique features of the Rogowski coils, combined with the highly adaptable input programming of our portable meters, allow for measurements in any application.
Common size:
MODEL | H-FCT-200 | H-FCT-350 | ||
Coil length | 200mm | 350mm | ||
Window size | 60mm | 105mm | ||
Reference Rated current | 600A | 3000A | ||
Weight | Approx 100-120g | |||
Output (di/dt) | 6.8mV/kA@50z±5% 8.16mV/kA@60z±5% 1.2mV/kA@50z±5% 1.44mV/kA@60z±5% | |||
Read Accuracy | Calibrated <0.5% (central position, 25℃) Uncalibrated < 5% tolerance (central position, 25℃) | |||
Maximum current measurable | 100kA | |||
Coil Resistance | 1A to 500kA | |||
Coil Section | 8mm | |||
Lead length | 2meter | |||
Temperature | Uncalibrated 200ppm/C | |||
Calibrated 300ppm/C | ||||
Position Error | ±1% maximum | |||
Output on 0A (zero drift) | ≤0.05mV | |||
Phase error | ≤0.5° | |||
Linearity | ±0.2% of reading | |||
Bandwidth | 1Hz to 100kHz(-3dB) | |||
Operating temperature | -30℃ to 80℃ | |||
Storage temperature | -40℃ to 90℃ | |||
Other requirements, please contact us to OEM. |