The installation steps and precautions for Flexible Rogowski Coils usually vary depending on the specific model and application scenario, but the following are some general installation guidelines:
1、 Installation steps
Determine installation location:
The Flexible Rogowski Coils should be installed at the center of mass of the object being measured to ensure measurement accuracy.
Choose a measurement environment with stable magnetic field and no interference.
Prepare installation tools and materials:
Prepare corresponding installation brackets, screws, nuts, and other tools and materials based on the model and specifications of the Flexible Rogowski Coils.
Ensure that the interface corresponds correctly to the coil pins and prepare necessary wiring tools.
Install the coil:
Wrap the Roche coil around the test wire to ensure a tight fit between the coil and the wire.
Use mounting brackets and screws to secure the coil to the wire, avoiding loosening or displacement of the coil.
If the coil has a positioning system (such as a "push together" or "screw connection" type), make sure to align and connect the coil ends correctly according to the instructions.
Wiring:
According to the pin identification of the coil, connect the red wire to the positive pole and the black wire to the negative pole.
Ensure that the wiring is secure and reliable, avoiding loose or short circuits.
Perform a power on test to prevent damage caused by misconnection.
Inspection and testing:
After installation, check if the coil is securely fixed and if the wiring is correct.
Conduct measurement accuracy testing on the coil in a testing environment that meets standard requirements to ensure that it is within the normal operating range.
2、 Precautions
Safe operation:
When installing and disassembling Flexible Rogowski Coilsw, ensure that the power is turned off to avoid the danger of live operation.
Use appropriate tools for operation to avoid damaging coils or wires.
Environmental requirements:
Avoid installing Flexible Rogowski Coils in strong magnetic field environments to avoid affecting measurement accuracy.
Keep the power cord away from the coil to reduce electromagnetic interference.
Maintenance and protection:
Regularly check the fixing condition of the coil to ensure that it is not loose or damaged.
During storage, prevent harmful substances such as dust and moisture from entering the coil.
Professional guidance:
For specific models or application scenarios of Flexible Rogowski Coils, it is recommended to refer to the product manual or contact the manufacturer for professional guidance.
In summary, the installation of Flexible Rogowski Coils requires following certain steps and precautions to ensure their measurement accuracy and safety. In practical operation, adjustments and adaptations should be made according to specific models and application scenarios.