Publish Time: 2024-09-26 Origin: Site
The installation method of Rogowski Coil will vary depending on its type (such as flexible coil or rigid coil) and specific application scenarios. The following are general installation steps and precautions:
1、 Preparation before installation
Confirm installation location: Select a suitable installation location based on the usage and actual needs of the Rogowski Coil.
Confirm installation direction: Based on the design requirements and installation position of the Rogowski Coil, confirm which direction it should face.
Clean installation point: Ensure that the installation point is clean, free of impurities and dust to ensure the working effect of the Rogowski Coil.
Security check: Conduct a security check on the installation location to ensure there are no safety hazards.
Preparation tools: It may be necessary to prepare wrenches, screwdrivers, pliers, flashlights or lamps, measuring tools (such as tape measures, vernier calipers), etc.
2、 Installation steps
Flexible Rogowski Coil
Winding coil: Wrap a flexible Rogowski Coil around the tested conductor to ensure a tight fit between the coil and the conductor.
Connection positioning system: The end of the coil is equipped with a positioning system (such as a "push together" or "screw connection" type) to ensure that they are correctly aligned and connected. If screw connection is used, it is more suitable for permanent installation; If the coil needs to be moved frequently, the push connection is more convenient.
Check the connection: Ensure that the two ends of the coil are correctly connected and check if the connection is secure.
Adjust position: Adjust the position of the Roche coil as needed to ensure accurate measurement of current.
Rigid Rogowski Coil
Fixed installation accessories: Fixing the installation accessories (such as brackets) of the rigid Rogowski Coil to the installation point usually requires the use of screws or other fasteners.
Install the coil: Install the rigid Rogowski Coil on the bracket to ensure it is stable and does not shake.
Connecting cable: Connect the coil to an integrator or other measuring device through a cable. The cable length can be adjusted as needed, but it should be ensured that the connection is firm and not disturbed.
3、 Check after installation
Check installation: After installation, conduct a comprehensive inspection of the Rogowski Coil to ensure that it is installed correctly, without looseness or misalignment.
Testing function: Conduct functional testing to verify whether the Rogowski Coil can work properly and accurately measure current.
4、 Precautions
Follow the instruction manual: During the installation process, be sure to follow the installation instructions and precautions for the Rogowski Coil.
Pay attention to safety: During the installation process, pay attention to safety and avoid electric shock or other accidental injuries.
Regular inspection: After installation, the working condition of the Rogowski Coil should be checked regularly to ensure that it always maintains good measurement performance.
Home About Us Products Resource News Contact Us Privacy Policy